DESKRIPSI ITEM
Size
5.1 x 2.8 x 2.0 in. / 13.1 x 7.0 x 5.2 cm
Weight
11.5 oz / 328 g
Operating Temperature
-4 to 122oF / -20 to 50oC
Humidity
10-100% RH (non-condensing)
Alarms and Type
Visual, Vibrating, Audibel (95 dB): Low, High, TWA, STEL, OL (Over Limit), Low Battery, Pump
Self-Test
Audibel / visual alarms on activation, sensors, battery, pump and circuitry (continuous)
Typical Battery Life
13 hours @ 32oF / 0oC
8 hours @ -4oF / -20oC
Recharges in 6 hours
Pump Draw
Sample from up to 75 ft. / 23 m
Note : Do not attempt to Calibrate a Honeywell BWTM Max XT with tubing longer than the standard calibration tubing supplied with the detector.
User Option
Confidence Beep
Safety (sensor) Lock
Latching Alarms
Safe Display Mode
Calibration IR Lock
Location Selection
Force block test
Force bump test when overdue
Force calibration when overdue
Sensor configuration
Detector Identification
Low alarm acknowledge
Language choices (five)
Set custom start-up message
Confidence interval
Datalog interval
Ratings Ingress Protection
EMI / RFI: Complies with EMC Directive 2004/108/EC IP66/67
Warrany
Full one year warranty including all sensors.
Sensor Specifications
Hydrogen Sulfide (H2S) : 0 ppm - 200 ppm
Carbon Monoxide (CO) : 0 ppm - 1000 ppm
Oxygen (O2) : 0% Vol - 30% Vol
Combustible Gases (LEL) : 0% LEL - 100% LEL
Part Number
XT-XWHM-Y-OE
Detil Produk
DESKRIPSI ITEM
Size
5.1 x 2.8 x 2.0 in. / 13.1 x 7.0 x 5.2 cm
Weight
11.5 oz / 328 g
Operating Temperature
-4 to 122oF / -20 to 50oC
Humidity
10-100% RH (non-condensing)
Alarms and Type
Visual, Vibrating, Audibel (95 dB): Low, High, TWA, STEL, OL (Over Limit), Low Battery, Pump
Self-Test
Audibel / visual alarms on activation, sensors, battery, pump and circuitry (continuous)
Typical Battery Life
13 hours @ 32oF / 0oC
8 hours @ -4oF / -20oC
Recharges in 6 hours
Pump Draw
Sample from up to 75 ft. / 23 m
Note : Do not attempt to Calibrate a Honeywell BWTM Max XT with tubing longer than the standard calibration tubing supplied with the detector.
User Option
Confidence Beep
Safety (sensor) Lock
Latching Alarms
Safe Display Mode
Calibration IR Lock
Location Selection
Force block test
Force bump test when overdue
Force calibration when overdue
Sensor configuration
Detector Identification
Low alarm acknowledge
Language choices (five)
Set custom start-up message
Confidence interval
Datalog interval
Ratings Ingress Protection
EMI / RFI: Complies with EMC Directive 2004/108/EC IP66/67
Warrany
Full one year warranty including all sensors.
Sensor Specifications
Hydrogen Sulfide (H2S) : 0 ppm - 200 ppm
Carbon Monoxide (CO) : 0 ppm - 1000 ppm
Oxygen (O2) : 0% Vol - 30% Vol
Combustible Gases (LEL) : 0% LEL - 100% LEL
Part Number
XT-XWHM-Y-OE