Detil Produk Turbidity Meter Hanna Instruments

Turbidity Meter Hanna InstrumentsTurbidity Portable Meter HI98703-01Turbidity SpecificationsRange0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTUResolution0.01; 0.1; 1 NTURange SelectionAutomaticAccuracy±2 % of reading plus 0.02 NTURepeatability±1 % of reading or 0.02 NTU, whichever is greaterStray Light
Dapatkan penawaran terbaik untuk Turbidity Meter Hanna Instruments !
Nama
Jumlah Order
Unit
IndoTrading.com adalah media iklan khusus perusahaan, distributor, Grosir, Agen, Supplier, Trading dan Pabrik. Jika anda tertarik untuk membeli Turbidity Meter Hanna Instruments ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika anda adalah perusahaan yang ingin menjual di IndoTrading.com ,
Detil Produk

Turbidity Meter Hanna Instruments

Turbidity Portable Meter HI98703-01

Turbidity Specifications

Range

0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU

Resolution

0.01; 0.1; 1 NTU

Range Selection

Automatic

Accuracy

±2 % of reading plus 0.02 NTU

Repeatability

±1 % of reading or 0.02 NTU, whichever is greater

Stray Light

< 0.02 NTU

Light Detector

Silicon photocell

Method

Ratio nephelometric method ( 90° & 180° )

Measuring Mode

Normal, average, continuous

Turbidity Standards

< 0.1, 15, 100, and 750 NTU

Calibration

Two, three, or four-point calibration

General Specifications

Light Source

Tungsten filament lamp / greater than 100,000 readings

Display

60 x 90 mm backlit LCD

Log Memory

200 records

Connectivity

USB or RS232

Environment

0 to 50 °C ( 32 to 122 °F ), RH max 95 % non-condensing

Power Supply

1.5V AA alkaline batteries ( 4 ) or AC adapter; auto-off after 15 minutes of non-use

Dimensions

224 x 87 x 77 mm ( 8.8 x 3.4 x 3.0” )

Weight

512 g ( 18 oz.)

Ordering Information

HI98703 is supplied with sample cuvettes and caps ( 5 ), HI98703-11 calibration cuvettes, silicone oil, cuvette wiping cloth, batteries, AC adapter, instruction manual, and rugged carrying case.

Portable Turbidity Meter ISO Compliant HI93703

Specifications

Range

0.00 to 1000 FTU

Resolution

0.01 ( 0.00 to 50.00 FTU ); 1 (50 to 1000 FTU )

Accuracy

±0.5 FTU or ±5 % of reading ( whichever is greater )

Calibration

Three points ( 0 FTU, 10 FTU and 500 FTU )

Light Detector

Silicon photocell

Light Source / Life

Infrared LED / life of instrument

Battery Type / Life

1.5 V AA ( 4 ) /approximately 60 hours of continuous use or 900 measurements; auto-off after 5 minutes of non-use

Environment

0 to 50 °C ( 32 to 122 °F ); RH max 95 % ( non condensing )

Dimensions

220 x 82 x 66 mm ( 8.7 x 3.2 x 2.6’’ )

Weight

510 g ( 1.1 lb.)

Ordering Information

Each HI93703 ( meter only ) is supplied complete with: glass cuvette with cap, batteries ( 4 x 1.5V AA ), and instructions.

Each HI93703C is a complete kit supplied with: 2 glass cuvettes with caps, batteries ( 4 x 1.5V AA ) and instructions, HI93703-0 & HI93703-10 cal. solutions, HI93703-50 cleaning solution, tissue for wiping cuvettes, adn a rugged carrying case.

Portable ISO Compliant Turbidity Meter with Data Logging and PC Connectivity HI93703-11

Turbidity Specifications

Turbidity Range

0.00 to 50.00 and 50 to 1000 FTU

Turbidity Resolution

0.01 ( 0.00 to 50.00 FTU ); 1 ( 50 to 1000 FTU )

Turbidity Accuracy

±0.5 FTU or ±5 % of reading ( whichever is greater )

Turbidity Calibration

Three points ( 0 FTU, 10 FTU and 500 FTU )

Turbidity Light Source

Infrared LED

Turbidity Light Detector

Silicon photocell

General Meter

Logging Type

On-demand

Logging Memory

199 measurements

Connectivity

Through serial port using HI 920011 connection cable and HI 92000 Windows® compatible software

Automatic Shut-Off

Auto-off after 5 minutes of non-use

Battery Type / Life

1.5 V AA ( 4 ) /approximately 60 hours of continuous use or 900 measurements

Environment

0 to 50 °C ( 32 to 122 °F ); RH max 95 % ( non condensing )

Dimensions

220 x 82 x 66 mm ( 8.7 x 3.2 x 2.6’’ )

Weight

510 g ( 1.1 lb.)

Ordering Information

HI93703-11 is supplied complete with glass cuvette with cap, batteries, and instructions.

Turbidity and Chlorine Portable Meter HI93414-01

Turbidity Specifications

Range

0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU

Resolution

0.01; 0.1; 1 NTU

Range Selection

Automatic

Accuracy

±2 % of reading plus 0.02 NTU

Repeatability

±1 % of reading or 0.02 NTU, whichever is greater

Stray Light

< 0.02 NTU

Light Detector

Silicon photocell

Method

Ratio nephelometric method ( 90° & 180° )

Measuring Mode

Normal, average, continuous

Turbidity Standards

< 0.1, 15, 100, and 750 NTU

Calibration

Two, three, or four-point calibration

Free and Total Chlorine Specifications

Free and Total Chlorine Range

0.00 to 5.00 mg/L ( ppm )

Free and Total Chlorine Resolution

0.01 mg/L ( ppm ) from 0.00 to 3.50 mg/L ( ppm ); 0.10 above 3.50 mg/L ( ppm )

Free and Total Chlorine Accuracy

±0.02 mg/L @ 1.00 mg/L

Light Detector

Silicon photocell with 525 nm narrow band interference filter

Method

Adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G.

Standards

1.00 mg/L ( ppm ) free chlorine; 1.00 mg/L ( ppm ) total chlorine

Calibration

One-point calibration

General Specifications

Light Source

Tungsten filament lamp / greater than 100,000 readings

Display

40 x 70 mm graphic LCD ( 64 x 128 pixels ) with backlight

Log Memory

200 records

Connectivity

USB or RS232

Environment

0 to 50 °C ( 32 to 122 °F ), RH max 95 % non-condensing

Power Supply

1.5 V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use

Dimensions

224 x 87 x 77 mm ( 8.8 x 3.4 x 3.0” )

Weight

512 g ( 18 oz.)

Ordering Information

HI93414 is supplied with sample cuvettes and caps ( 5 ), calibration cuvettes for turbidity and chlorine, silicone oil, cuvette wiping cloth, scissors, batteries, AC adapter, instruction manual, and rugged carrying case.

ISO Turbidity Portable Meter HI98713-01

Turbidity Specifications

Range

0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU

Resolution

0.01; 0.1; 1 FNU

Range Selection

Automatic

Accuracy

±2 % of reading plus 0.1 FNU

Repeatability

±1 % of reading or 0.01 FNU, whichever is greater

Stray Light

< 0.1 FNU

Light Detector

Silicon photocell

Method

Ratio nephelometric method ( 90° & 180° )

Measuring Mode

Normal, average, continuous

Turbidity Standards

< 0.1, 15, 100 and 750 FNU

Calibration

Two, three, or four-point calibration

General Specifications

Light Source

860 nm IR LED / greater than 100,000 readings

Log Memory

200 records

Connectivity

USB or RS232

Environment

0 to 50 °C ( 32 to 122 °F ), RH max 95 % non-condensing

Power Supply

1.5V AA batteries ( 4 ) / 12 VDC adapter; auto-off after 15 minutes of non-use

Dimensions

224 x 87 x 77 mm ( 8.8 x 3.4 x 3.0” )

Weight

512 g ( 18 oz.)

Ordering Information

HI98713 is supplied with sample cuvettes and caps ( 5 ), HI98713-11 calibration cuvettes, silicone oil, cuvette wiping cloth, batteries, AC adapter, instructions, and rugged carrying case.

Portable Multiparameter Turbidity and Ion Specific Meter HI93102

Turbidity Specifications

Turbidity Range

0.00 to 50.0 NTU

Turbidity Resolution

0.01 (0.00 to 9.99); 0.1 NTU (10.0 to 50.0)

Turbidity Accuracy

±0.5 NTU or ±5 % of reading ( whichever is greater )

Turbidity Calibration

Two-point; selectable between 0.00 - 50.0 FTU ( 0.00 and 20.0 FTU recommended )

Bromine Specifications

Bromine Range

0.00 to 8.00 mg/L ( ppm )

Bromine Resolution

0.01 mg/L ( ppm )

Bromine Accuracy

±0.08 mg/L ( ppm ) ; ±3 % of reading

Free and Total Chlorine Specifications

Chlorine Range

Free : 0.00 to 2.50 mg/L ( ppm ); Total: 0.00 to 3.50 mg/L ( ppm )

Chlorine Resolution

0.01 mg/L ( ppm )

Chlorine Accuracy

±0.03 mg/L ( ppm ); ±3 % of reading

Cyanuric Acid Specifications

Cyanuric Acid Range

0 to 80 mg/L ( ppm )

Cyanuric Acid Resolution

1 mg/L ( ppm )

Cyanuric Acid Accuracy

±1 mg/L ( ppm ); ±15 % of reading

Iodine Specifications

Iodine Range

0.0 to 12.5 mg/L ( ppm )

Iodine Resolution

0.1 mg/L ( ppm )

Iodine Accuracy

±0.1 mg/L ( ppm ) ; ±5 % of reading

Iron LR Specifications

Iron Range

0.00 to 1.00 mg/L ( ppm )

Iron Resolution

0.01 mg/L ( ppm )

Iron Accuracy

±0.02 mg/L ( ppm ); ±3 % of reading

pH Specifications

pH Range

5.9 to 8.5 pH

pH Resolution

0.1 pH

pH Accuracy

±0.1 pH

Specifications

Light Detector

Silicon photocell ( 2 )

Light Source / Life

Pure green LED

Battery Type / Life

1.5 V AA ( 4 ) / approximately 60 hours of continuous use or 1000 measurements; automatic shut-off selectable after 10, 20, 30, 40, 50 or 60 minutes of non-use

Environment

0 to 50 °C ( 32 to 122 °F ); RH max 95 % ( non condensing )

Dimensions

220 x 82 x 66 mm ( 8.7 x 3.2 x 2.6’’ )

Weight

510 g ( 1.1 lb.)

Ordering Information

HI93102 is supplied with measurement cuvette cap, batteries and instruction manual.

Alat Ukur Kekeruhan