Dari TFIA 2 High Volume Air Sampler Staplex 0
Dari TFIA 2 High Volume Air Sampler Staplex 1
Dari TFIA 2 High Volume Air Sampler Staplex 2
Dari TFIA 2 High Volume Air Sampler Staplex 3
Dari TFIA 2 High Volume Air Sampler Staplex 4
Dari TFIA 2 High Volume Air Sampler Staplex 5
Dari TFIA 2 High Volume Air Sampler Staplex 6
Dari TFIA 2 High Volume Air Sampler Staplex 7

TFIA 2 High Volume Air Sampler Staplex

Pembelian Minimum 1
Negara Asal United States
Update Terakhir 07 Des 2019
Harga
CALL

Penjual

PSC

Verified Supplier
Free Member
Alamat

Lindeteves Trade Center LTC Lantai 1 Blok B 21 No.3 Jl. Hayam Wuruk 127 Glodok Jakarta Barat 11180

Detil Produk TFIA 2 High Volume Air Sampler Staplex

High Volume Air Sampler TFIA 2 StaplexSpesificationHigh Volume Air Samplers ( HVAS )ApplicationAir Sampler Indoor and OutdoorMotor/PumpBrushed, 2-Stage Blower.Main HousingSturdy Lightweight DuralMax Flow Rate40 CFMUnit Weight9 LbsPower Supply230 VAC, 50/60 Hz, 5.5 AmpFilter holder4 inch diameterFilt
Dapatkan penawaran terbaik untuk TFIA 2 High Volume Air Sampler Staplex !
Nama
Jumlah Order
Unit
IndoTrading.com adalah media iklan khusus perusahaan, distributor, Grosir, Agen, Supplier, Trading dan Pabrik. Jika anda tertarik untuk membeli TFIA 2 High Volume Air Sampler Staplex ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika anda adalah perusahaan yang ingin menjual di IndoTrading.com ,
Detil Produk

High Volume Air Sampler TFIA 2 Staplex

Spesification

High Volume Air Samplers ( HVAS )

Application

Air Sampler Indoor and Outdoor

Motor/Pump

Brushed, 2-Stage Blower.

Main Housing

Sturdy Lightweight Dural

Max Flow Rate

40 CFM

Unit Weight

9 Lbs

Power Supply

230 VAC, 50/60 Hz, 5.5 Amp

Filter holder

4 inch diameter

Filter paper

4 inch diameter

Accessories

Filter Paper

4" Glass Fiber Filter Paper ( 100 sheet/box )

Air Flow Adjust

Min Air Flow 0.3 Cubic meters per minute

Tripod

Included Steel Plate

Staplex® Model TFIA series High Volume Air Samplers

Indoor or outdoor sampling of airborne particulates

0-70 cubic feet per minute ( cfm ) [ 0-2 cubic meters per minute ( cmm )] flow range

Spot or continuous monitoring

Portable and lightweight

Built-in rotometer for instantaneous flow reading

Includes 4" ( 10.16 cm ) diameter filter holder assembly

For use in normal, non-explosive atmospheres

Complete accessories available for use with Total Suspended Particulate ( TSP ), PM10 and PM2.5 Systems for U.S. EPA compliance

Made in U.S.A.

Standard Models :

Note for 110-125 volt and 220-230 volt models:

- F feature includes built in flow adjuster

- CDT Time feature allows to turn "OFF" or "ON" after a preset time or for use as an Elapsed Time Indicator )

TFIA 110-125 Volts AC/DC, 50-60 Hz Basic model best seller!

TFIA-F Includes built-in Flow Adjuster - 110-125 Volts AC/DC, 50-60 Hz

TFIA-CDT Includes built-in Count Down Timer - 110-125 Volts AC/DC, 50-60 Hz ( Note : CDT feature allows to turn "OFF" or "ON" after a preset time or for use as an Elapsed Time Indicator )

TFIA-FCDT Includes built-in Flow Adjuster and Count Down Timer - 110-125 Volts AC/DC, 50-60 Hz

TFIA-2 220-240 Volts AC/DC, 50-60 Hz Basic model best seller!

TFIA-2F Includes built-in Flow Adjuster - 220-240 Volts AC/DC, 50-60 Hz

TFIA-2CDT Includes built-in Count Down Timer - 220-240 Volts AC/DC, 50-60 Hz

TFIA-2FCDT Includes built-in Flow Adjuster and Count Down Timer - 220-240 Volts AC/DC, 50-60 Hz

TFIA-4 24 Volts DC ( 35 cfm [ 1 cmm ] maximum flowrate ) 16 Amps

TFIA-4BC 24 Volts DC with battery cable with clamps, 16 Amps

When normal currents are not available 24 Volts DC models are ideal for remote field use.

Model TFIA-4BC with 2 of 12 Volt DC automobile batteries in series ( or at lower flowrate with 1 of 12 Volt DC battery.)

 

12 VDC

24 VDC

4" Filter flowrate

0.8 cfm ( 0.3 cmm )

18 cfm ( 0.5 cmm )

8" x 10" Filter flowrate

18 cfm ( 0.5 cmm )

26 cfm ( 0.8 cmm )

cfm = cubic feet per minute; cmm = cubic meters per minute

Use Model TFIA-4 with Portable Re-chargable Battery Pack and Charger:

Model TF24B Battery Pack ( 20 minute run time on full charge; 6 hour recharge time ) shown on left with optional carrying case with shoulder strap

Model TF24CU Battery Charger ( 110-125 VAC ) for TF24B Battery Pack

Model TF24CU Battery Charger ( 220-240 VAC ) for TF24B Battery Pack

Other special model High Volume Air Samplers also available.

Gasoline and diesel generators available for TFIA ( 110-125 V ) and TFIA-2 ( 220-230 ) Series High Volume Air Samplers. Request details.

Specifications for TFIA Series :

Dimensions : 8-½ " x 7-½" x 7-1/2 ( 21.6 x 19.1 x 19.1 cm )

Carrying weight : 10 lbs. ( 4.5 kg )

Construction : Sturdy Lightweight Dural Main Housing

Description

Portable Air Sampler for indoor and outdoor sampling for all types of airborne particulates including environmental pollutants, nuclear and biohazards, industrial, governmental and military tests and studies, mine air hazards, factory dusts, chemical, radiological and toxicological analyses, as well as innumerable other types of research, quality control and testing applications.

Principle of Operation

Large volumes of air are drawn through a filter by a high-speed rotary motor. Particulate matter in the air collects on various types and sizes of filter papers including Glass Fiber Filter Media.

Standard Features

Universal motor, Pump, Variable Orifice Flowmeter calibrated 0-70 CFM or 0-2 CMM; 4" ( 10.16 cm ) diameter Filter Holder Assembly, Filter Support Rod and Stainless Steel Mesh Adapter, carrying handle, on/off current toggle switch, 8 foot ( 38 cm ) grounded cordset.

Analysis of Collected Samples

Filters can be analyzed gravimetrically, by weighing, taring, ashing, spectrography, atomic absorption, comparator, microscopic count, chromatography, atomic colorimetric assay, and gamma­ray spectroscopy, x-ray fluorscopy and neutron ac­tivation etc., to identify pollutants and measure their concentrations.

Operation

Proper filter is inserted into appropriate filter holder of air sampler and sampler is then ready for test operations. Initial flow rate and sampling time are recorded. Flow rate is governed by size and type of filter used. ( See Chart A Filters )

The Staplex SH4 4" Diameter Filter Holder Assembly, is equipped with filter support rod to be used as back support for Staplex TFA2133 filters. In addition. when using Staplex TFA41 Filter Paper and Staplex TFAGF41 Glass Fiber Filters, a special 4 " Diameter Stainless Steel Screen is required ( included ).

Calibration

The rate of flow is measured by means of an indirect, variable orifice flow meter ( pressure indicator gauge ). This indicates the pressure drop across an orifice in the housing and is calibrated against a standard orifice on the intake. Flowrate is determined by saturation of filter paper and should be recorded accordingly during sampling test periods. User can calibrate the flow meter in the field using the US EPA prescribed method for calibrating High Volume Air Samplers, using Staplex Model CKHV and CKHV810 Calibration Kits. ( See additional data sheet )

General

Can be used indoors or outdoors. for mobile or fixed position operation either horizontally or vertically. Also available is a convenient Staplex TR-1 Tripod moun­ting. When required for protracted periods outdoors a special outdoor enclosed shelter in Aluminum ( SAM ) or Wooden ( SWM ) is available.

Maintenance

TFIA series models can be operated continuously when using TFA810 and TFAGF810 8" x 10" filters continuously, with filters checked and changed as need, based on particulate saturation. No lubrication of any motor parts is required. Motor brushes should be check after every 600 hours of usage and changed as needed. Changing of brushes is recommended for every 800 - 1,000 hours of usage.

Accessories

Filters

TFA41 Filter Paper 4" dia. ( 100/box )

TFAGF41 Glass Fiber Filters 4" dia. ( 100/box )

TFAQ41 Quartz Filter 4" dia. ( 100/box )

TFA810 Filter Paper 8" x 10" ( 100/box )

TFAGF810 Glass Fiber Filters 8"x10" ( 100/box )

TFAQ810 Quartz FIlter 8" x 10" ( 25/box )

TFA69 Filter Paper 6" x 9" ( 100/box )

TFAGF69 Glass Fiber Filters 6" x 9" ( 100/box )

TFA2133 Filters, 4" diameter ( 100/box )

Alat Ukur dan Instrumen