Survey Meter PM1405 PolimasterSpecificationsDetectorGeiger-Muller counterDose equivalent rate ( DER ) measurement range0.1 μSv/h − 100 mSv/hDER indication range0.01 μSv/h − 130 mSv/hDER measurement accuracy± ( 20 + K/H ) %, where Ḣ – dose rate, μSv/h K - coefficient
Dapatkan penawaran terbaik untuk Survey Meter PM1405 Polimaster !
Nama
Jumlah Order
Unit
IndoTrading.com adalah media iklan khusus perusahaan, distributor, Grosir, Agen, Supplier, Trading dan Pabrik. Jika anda tertarik untuk membeli Survey Meter PM1405 Polimaster ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika anda adalah perusahaan yang ingin menjual di IndoTrading.com ,
Detil Produk

Survey Meter PM1405 Polimaster

Specifications

Detector

Geiger-Muller counter

Dose equivalent rate ( DER ) measurement range

0.1 μSv/h − 100 mSv/h

DER indication range

0.01 μSv/h − 130 mSv/h

DER measurement accuracy

± ( 20 + K/H ) %, where Ḣ – dose rate, μSv/h K - coefficient 1.0 μSv/h

Dose equivalent ( DE ) measurement range

1.00 μSv − 10.0 Sv

DER indication range

0.01 μSv − 10.0 Sv

DE measurement accuracy

± 20 %

Alarm Type

audible, visual

Thresholds

available for all types of radiation

Energy range: Photon radiation

from 0.05 to 3.0 MeV

Energy response relative to 0.662 MeV : in the energy range from 0,05 to 3,0 MeV, no more than

± 30 %

β- radiation flux density measurement range

from 6.0 to 103 min-1•cm² ( cpm/cm² )

β- radiation flux density accuracy : 90Sr+90Y

± ( 20 + А/φ ) %, where φ – measured β-flux density, min-1•cm² ( cpm/cm² ); А – coefficient, 60 min-1•cm² ( cpm/cm² ));

β-particle flux indication range

from 0.1 to 104 min-1•cm² ( cpm/cm² )

Energy range by β-particle flux density measurement

from 0.1 to 3.5 MeV

Energy response by β-particle flux density measurement

± 30 %

Sensitivity for β-radiation : 90Sr+90Y

3.5 counts·cm²

Count rate indication for β-γ radiation in the search mode

from 0.00 to 3.5·105 s-1 ( cps )

α-radiation flux density measurement range

from 90 to 104 min-1•cm² ( cpm/cm² )

α- radiation flux density accuracy : in 239 Pu measurement range

± ( 30 + А/φ ) %, where φ − measured α- flux density, min-1•cm² ( cpm/cm² ); A – coefficient equat to the 900 min-1•cm ( cpm/cm² )

α- particle flux density indication range

from 0.1 to 104min-1•cm² ( cpm/cm² )

PC communication

USB interface

Operation mode setup time, no more

60 s

Power supply

two AA batteries 3 ( + 0.2; -0.8 ) V; external power supply

Battery lifetime : - at an average value of the measured DER up to 0.3 μSv/h; - using LCD backlight, audible and visual alarm not more than 5 m/day, no more than

6 months

Ingress protection

IP30

Drop test on concrete floor

0.7 m

Dimensions

148 х 80 х 38 mm

Weight

0.29 kg

Operating temperature

-10 °C to 50 °C ( 14 °F to 122 °F C27 )

Humidity

up to 95 % at 35 °С

Atmospheric pressure

from 84 up to 106.7 kPa

Mean service lifetime

10 years