Dari Surabaya  Oscilloscopes-Oscilloscope HANTEK DSO5102P 0

Surabaya Oscilloscopes-Oscilloscope HANTEK DSO5102P

Pembelian Minimum 1
Negara Asal United States
Update Terakhir 04 Jan 2019
Harga
CALL

Penjual

Tohodo Scientific Instrument

Verified Supplier
Alamat

DTC (Darmo Trade Center) LT.4 Blok A No.63 Jl. Raya Wonokromo Surabaya, Jawa Timur

No. Telepon

+628XXXXXXXX

No. Whatsapp

Klik Disini

Detil Produk Surabaya Oscilloscopes-Oscilloscope HANTEK DSO5102P

Oscilloscopes-Oscilloscope HANTEK DSO5102P1.Feature100MHz bandwidths1GSa/s Real Time sample rateLarge (7.0-inch) color display,WVGA(800x480)Record length up to 40KTrigger mode: edge/pulse width/line selectable video/slop/overtime etc.USB host and device connectivity, standardMultiple automatic measu
Dapatkan penawaran terbaik untuk Surabaya Oscilloscopes-Oscilloscope HANTEK DSO5102P !
Nama
Jumlah Order
Unit
IndoTrading.com adalah media iklan khusus perusahaan, distributor, Grosir, Agen, Supplier, Trading dan Pabrik. Jika anda tertarik untuk membeli Surabaya Oscilloscopes-Oscilloscope HANTEK DSO5102P ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika anda adalah perusahaan yang ingin menjual di IndoTrading.com ,
Pencarian Surabaya Oscilloscopes-Oscilloscope HANTEK DSO5102P
Detil Produk

Oscilloscopes-Oscilloscope HANTEK DSO5102P

1.Feature
100MHz bandwidths
1GSa/s Real Time sample rate
Large (7.0-inch) color display,WVGA(800x480)
Record length up to 40K
Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
USB host and device connectivity, standard
Multiple automatic measurements
Four math functions, including FFTs standard
Provides software for PC real-time analysis
VGA Optional

2.Specifications
Model : DSO5102P
Acquisition
Sample Rate : Real-Time Sample: 1GS/s
Acquisition Modes     
Normal : Normal data only
Peak Detect : High-frequency and randon glith capture
Average : Wavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling : AC, DC, GND
Inputs Impendance : 1MΩ±2% ‖20pF±3pF
Probe Attenuation : 1X,10X
Supported Probe Attenuation Factor : 1X,10X,100X,1000X
Maximum Input Voltage :
CAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×);
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal System :
Sample Rate Range : 500MS/s--1GS/s
Waveform Interpolation :(sin x)/x
Record Length : 40K
SEC/DIV Range : 4ns/div to 40s/div
Sample Rate and Delay Time Accuracy : ±50ppm(at over any ≥1ms time interval)
Position Range :
20ns/div to 80us/div; (-8div x s/div) to 40ms;
200us/div to 40s/div; (-8div x s/div) to 400s
Delta Time Measurement Accuracy (Full Bandwidth) :
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200
Vertical System
Vertical Resolution : 8-bit resolution, all channel sampled simultaneously
Position Range : 2mV/div to 10V/div
Bandwidth : 100MHz
Rise Time at BNC(typical) : 3.5ns
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled : 2mV/div to 20mV/div, ±400mV;  50mV/div to 200mV/div, ±2V
500mV/div to 2V/div, ±40V; 5V/div, ±50V
Math : +, -, *, /, FFT
FFT : Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
1024 sample point
Bandwidth Limit : 20MHz
Low Frequency Response(-3db) : ≤10Hz at BNC
DC Gain Accuracy :
±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy,
Average Acquisition Mode :
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;
When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability,
Average Acquisition Mode : Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types : Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source : CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes : Auto, Normal, Single
Coupling Type : DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity(Edge Trigger Type) :
DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz;       
AC: Attenuates signals below 10Hz;
HF Reject: Attenuates signals above 80kHz
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range :
CH1/CH2: ±8 divisions from center of screen;
EXT: ±1.2V;
EXT/5:±6V
Trigger Level Accuracy(typical)Accuracy is for signals having rise and fall times ≥20ns :    
CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
EXT: ± (6% of setting + 40mV);
EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical) : Operates with input signals ≥50Hz
Video Trigger     
Video Trigger Type : CH1, CH2: Peak-to-peak amplitude of 2 divisions;
EXT: 400mV;
EXT/5: 2V
Signal Formats and Field Rates, Video Trigger Type : Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range : 100ns~10s
Pulse Width Trigger     
Pulse Width Trigger Mode : Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger Point :
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range : 20ns ~ 10s
Slope Trigger     
Slope Trigger Mode : Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger Point :
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range : 20ns ~ 10s
Overtime Trigger     
Over Time Mode : Rising edge or Falling edge
Time Range : 20ns ~ 10s
Alternative Trigger :     
Trigger on CH1     :
Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2 :      
Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution : 6 digits
Accuracy(typical): ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range : AC coupled, from 4Hz minimum to rated bandwidth