Dari Petroleum Gauging Thermometer Digital TP9 ThermoProbe 0
Dari Petroleum Gauging Thermometer Digital TP9 ThermoProbe 1
Dari Petroleum Gauging Thermometer Digital TP9 ThermoProbe 2

Petroleum Gauging Thermometer Digital TP9 ThermoProbe

Pembelian Minimum 1
Negara Asal United States
Update Terakhir 24 Sep 2019
Harga
CALL

Penjual

PSC

Verified Supplier
Free Member
Alamat

Lindeteves Trade Center LTC Lantai 1 Blok B 21 No.3 Jl. Hayam Wuruk 127 Glodok Jakarta Barat 11180

Detil Produk Petroleum Gauging Thermometer Digital TP9 ThermoProbe

Petroleum Gauging Thermometer Digital TP9 ThermoProbeSpecificationsMaximum Dimensions10” L x 4.25” H x 6.4” WWeight3.1 lb ( 1.4 kg ) – with 75' standard weight probe assemblyProbeStainless Steel, Sealant, Aramid Fiber Reinforced, FEP or PFA Cable Jacket, Coaxial Construct
Dapatkan penawaran terbaik untuk Petroleum Gauging Thermometer Digital TP9 ThermoProbe !
Nama
Jumlah Order
Unit
IndoTrading.com adalah media iklan khusus perusahaan, distributor, Grosir, Agen, Supplier, Trading dan Pabrik. Jika anda tertarik untuk membeli Petroleum Gauging Thermometer Digital TP9 ThermoProbe ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika anda adalah perusahaan yang ingin menjual di IndoTrading.com ,
Detil Produk

Petroleum Gauging Thermometer Digital TP9 ThermoProbe

Specifications

Maximum Dimensions

10” L x 4.25” H x 6.4” W

Weight

3.1 lb ( 1.4 kg ) – with 75' standard weight probe assembly

Probe

Stainless Steel, Sealant, Aramid Fiber Reinforced, FEP or PFA Cable Jacket, Coaxial Construction

Enclosure Material

Stainless Steel Static-dissipative Plastic Probe Holder

Batteries

2 AA Alkaline; Battery Life of approximately 200 hours Battery manufacturer’s battery operating temperature range -4 to 130°F, -20 to 54 °C Note : Battery may not provide adequate power if ambient temperature is extremely low or high.

Temperature

Resolution 0.01 Range : -40 to 400 °F -40 to 204 °C Calibrated Accuracy : ±0.2 °F from 32 to 200 °F ±0.5 °F from 200 to 400 °F ±0.1 °C from 0 to 100 °C ±0.3 °C from 100 to 200 °C 4 Point NIST Traceable Report of Test Long-term drift not to exceed 0.05 % / year Meets API requirements

Certification

ATEX & IECEx ( Ex ia IIB T4 Ga )

Temperature

Resolution

0.01 Degrees

Range

- 40 °F to 400 °F ( -40 °C to 204 °C )

Note

Standard Calibration does not provide full range accuracy

Calibrated Accuracy

± 0.2 °F from 32 to 200 °F ( ± 0.1 °C from 0 to 100 °C )

± 0.5 °F from 200 to 400 °F ( ± 0.3 °C from 100 to 200 °C )

Custom calibration points and ranges available.

4 Point NIST Traceable Report of Test Long-term drift not to exceed 0.05 %/year Meets API require

Interface Features

½" ( 13 mm ) character LCD

Switchable units °C or °F

Resolution 0.1 or 0.01

Low Battery & Fault Indication

Calibration adjustment through faceplate buttons.

Auto Off after 20 minutes.

Stores and displays up to 10 Logged readings, Average, Lowest

& Highest readings.

Arrows indicating increasing/decreasing temperature.

Recommended Ambient Temperature range : 32 °F to 112 °F ( 0 °C to 44 °C )

Construction

Probe

304 Stainless Steel, Sealant, Coaxial cable with Aramid Fiber & PFA Cable Jacket

Enclosure

Stainless Steel

Rugged panel mount buttons

Static Dissipative Plastic Handle

Nominal Body Dimensions

10” L x 4.25” H x 6.4” W ( 11.4 x 4.4 x 4.4 cm )

Nominal Weight

3.1 lb ( 1.4 kg ) with 75′ standard weight probe assembly

Battery

2 AA Alkaline; Battery Life of approximately 200 hours

Battery manufacturer’s battery operating temperature range - 4 to 130 °F ( -20 to 54 °C )

Note

Battery may not provide adequate power if ambient temperature is extremely low or high.

Typical Applications

Custody Transfers, Hazardous Location, Intrinsically safe, Inventory, PET, Tank, Pipeline, Barge, Ship, Railcar, Tank ,Truck

Materials

Gasoline, Diesel, Asphalt, Molten Sulphur, Petrochemical, Viscous, Caustic, Acid, Chemical, Alkali, Molasses, Syrup, Distilled spirits, Aviation fuel

Recommended Operations

API 7 : International Safety Guide for Oil Tankers and Terminals, API 4 and other recognized procedures and standards.

Termometer Digital