Dari KYORITSU KEW 5010 - Logger 0

KYORITSU KEW 5010 - Logger

Pembelian Minimum 1
Negara Asal Japan
Update Terakhir 07 Jan 2020
Harga
CALL

Penjual

CV. Andalan Prima Sejahtera

Verified Supplier
1 Tahun
Alamat

Perum. Bintang Metropol Jl. Jupiter VI , Blok A7 No 16 Bekasi Utara – Indonesia. 17122

Detil Produk KYORITSU KEW 5010 - Logger

KYORITSU KEW 5010 - LoggerFeatures3 channel inputs for the simultaneous recording of Leakage Current and Load Current• Large capacity for storing 60,000 data points• Lowpass Filter will filter out the harmonics• LED flickers when the preset current value is exceeded• CALL:Confirm
Dapatkan penawaran terbaik untuk KYORITSU KEW 5010 - Logger !
Nama
Jumlah Order
Unit
IndoTrading.com adalah media iklan khusus perusahaan, distributor, Grosir, Agen, Supplier, Trading dan Pabrik. Jika anda tertarik untuk membeli KYORITSU KEW 5010 - Logger ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika anda adalah perusahaan yang ingin menjual di IndoTrading.com ,
Detil Produk

KYORITSU KEW 5010 - Logger

Features

3 channel inputs for the simultaneous recording of Leakage Current and Load Current

• Large capacity for storing 60,000 data points
• Lowpass Filter will filter out the harmonics
• LED flickers when the preset current value is exceeded
• CALL:Confirmation of recorded data
• Selection of One-time mode or Endless mode
• Non Volatile Memory
• Battery power indicator
• The userfriendly PC software "KEW LOG Soft 2" is supplied
• Continuous measuring time:Approx. 10 days (Alkaline Battery)

Specification

  • 3 channel inputs for the simultaneous recording of Leakage Current, Load Current and Voltage
  • Large Capacity for storing 60,000 data points
    • 60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recorded
  • Lowpass Filter will filter out the harmonics (Cutoff Frequency = Approx. 160Hz)
  • LED flickers when the preset current value is exceeded
  • CALL: Confirmation of recorded data
    • The following can be displayed: number of recorded data points, (max+ min+ peak) value for each channel complete with time/date information in the Normal recording mode. (Detected values (i.e. when values are outside preset limits ) can be displayed in other recording modes)
    • RECALL: The last 10 recorded data points including time/date can be recalled on the logger display
  • Selection of One-time mode or Endless mode
    • One-time on: Recording will stop when memory is used up
    • One-time off: Overwrite the old data, and store the latest data
  • Non Volatile Memory
    Recorded data will be retained even if the batteries are exhausted or replaced due to the presence of a nonvolatile memory (guaranteed for 10 years)
  • Battery power indicator
    Indicates battery voltage in 4-levels
    (It is possible to use the logger for a further approx. 24 hours even after the warming symbol is flashing)
  • The userfriendly PC software "KEW LOG Soft 2" is supplied
    • Supplied with the user friendly software "KEW LOG Soft 2". This permits editing, analysis and graphical display of data.
    • The recorded data is downloadable onto a PC via USB cable.
  • Continuous measuring time: Approx. 10 days (Alkaline Battery)

Normal Recording Mode
(AC 50/60Hz, Sine wave, Input: 10% or more of the range at CH1)

RangeRMS Accuracy
100.0mA±2.0%rdg±0.9%f.s.+ Accuracy of Sensor
Other ranges±1.5%rdg±0.7%f.s.+ Accuracy of Sensor
Crest Factor2.5 or less: RMS accuracy (sine) + 2%rdg + 1%f.s.

*Max, Min and Instant Peak values in Normal Recording mode are just reference values:
their accuracies aren't guaranteed.

Trigger Recording Mode (AC 50/60Hz sine wave)

RangeAccuracy
100.0mA±3.5%rdg±2.2%f.s.+ Accuracy of Sensor
Other ranges±3.0%rdg±2.0%f.s.+ Accuracy of Sensor

Capture Recording Mode

RangeAccuracy
100.0mA±3.0%rdg±1.7%f.s.+ Accuracy of Sensor
Other ranges±2.5%rdg±1.5%f.s.+ Accuracy of Sensor
Recording modeNormal, Trigger, Capture
Operating systemSuccessive Approximation
(CH1 single synchronized sampling)
Rated max. working voltageAC 9.9Vrms, 14V peak value
Number of input channel3ch
Measuring methodTrue RMS
RMS measuring intervalapprox. 100ms
Sampling intervalNormal/Trigger mode : approx. 1.65ms/CH 
Capture mode : approx. 0.55ms (waveform: at every 1.1ms)
Low battery warningBattery mark display (in 4 levels)
Over-range indication"OL" mark is displayed when exceeding the measuring range
Auto power offPower-off function operates automatically after a switch remains for 3min. (when recording is stopped)
Possible measurement timeApprox. 10 days (with alkaline LR6 batteries)
Applicable standardsIEC 61010-1:2001 CAT III 300V Pollution degree2
IEC 61326 (EMC standard)
Dimensions111(L)×60(W)×42(D)mm
WeightApprox. 265g
Included AccessoriesAlkaline battery LR6×4pcs, 9118 (Carrying case)
PC software "KEW LOG Soft 2", 7148 (USB cable)
Instruction manual, Quick manual, Install manual,
USB Notice sheet
Optional Accessories8146/8147/8148 (Leakage & Load current Clamp Sensor),
8121/8122/8123 (Load current Clamp Sensor),
8129/8130 (Flexible Clamp Sensor),
8320 (AC Adapter), 
9135 (Carrying bag), 9119 (Hard carry case),
7185 (Extension cable for sensor)