Dari InfraCal 2 ATR-E - Ethanol In Gasoline Analyzer 0

InfraCal 2 ATR-E - Ethanol In Gasoline Analyzer

Pembelian Minimum 1
Negara Asal United States
Update Terakhir 30 Mar 2019
Harga
Rp 001 *harga belum termasuk PPN

Penjual

PT ANDALAN BANGUN SEJAHTERA

Verified Supplier
3 Tahun
Alamat

Jl. Sumur Batu no. 1 Kemayoran Jakarta Pusat

Detil Produk InfraCal 2 ATR-E - Ethanol In Gasoline Analyzer

Alat Laboratorium AirInfraCal 2 ATR-E - Ethanol In Gasoline AnalyzerThe InfraCal 2 Ethanol Blend Analyzer for measuring percent ethanol in gasoline is the ideal solution where a quick, accurate, on-site measurement is required and a single, repetitive ethanol blend analysis is needed. 
Dapatkan penawaran terbaik untuk InfraCal 2 ATR-E - Ethanol In Gasoline Analyzer !
Nama
Jumlah Order
Unit
IndoTrading.com adalah media iklan khusus perusahaan, distributor, Grosir, Agen, Supplier, Trading dan Pabrik. Jika anda tertarik untuk membeli InfraCal 2 ATR-E - Ethanol In Gasoline Analyzer ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika anda adalah perusahaan yang ingin menjual di IndoTrading.com ,
Detil Produk

Alat Laboratorium Air

InfraCal 2 ATR-E - Ethanol In Gasoline Analyzer

The InfraCal 2 Ethanol Blend Analyzer for measuring percent ethanol in gasoline is the ideal solution where a quick, accurate, on-site measurement is required and a single, repetitive ethanol blend analysis is needed.  The InfraCal 2 ATR-E is based on proven IR technology, and used by fuel terminals, laboratories and regulatory agencies worldwide.  The compact, easy-to-use InfraCal 2 ATR-E has a measurement range of 0-20 & 70-98%% ethanol in gasoline and an accuracy of +/- 0.2%. These results are comparable to ASTM D4815.  

Samples are applied to a  zinc selenide attenuated total reflectance (ATR) sample plate and easily cleaned with a cloth & isopropyl alcohol.  No solvents requiring special ventilation, expensive waste disposal or difficult to clean cells are needed. The analysis can be done by non-technical personnel with no formal training and is ideal for lab or field use. The InfraCal2 ATR-E has a touch screen display, data storage and transfer, a multi-language interface and password protected settings.  The internal battery pack allows for portability and up to 12 hours continuous use, providing results in under a minute at a fuel loading rack, in a laboratory or at a pump in a fueling station.

  • Measurement range: 0 - 20 & 70 - 98% ethanol in gasoline
  • Instrument repeatability: +/- 0.2%
  • Compares to ASTM D4815

Highlights

  Benefits

  Features

Internal Data Storage

Data storage including each measurement tagged with analyst, location and date/time information, and password protected instrument settings

Export

Directly to your PC via USB or a Flash Drive

Touch Screen Display

The touch screen display allows a simple set up for quick operation along with an easy calibration wizard.

Internal Battery

The internal battery pack allows for portability and up to 6 hours continuous use.
Multi-Language Interface

English, Spanish, French, Arabic

Password Protected Settings

Calibration and data are password protected to avoid accidental deletion

No need for Installation/Commissioning

The InfraCal 2 is a portable analyzer, weighing less than 5 lbs. with a 6 in. square foot print, requiring no installation or commissioning, little to no routine maintenance or recalibration.

Minimal Consumables

The analysis requires little to no consumables making the cost-per-test minimal.

Specifications

ItemSpecifications
Analytical Wavelength/Wave Number9.6 µm, 1045cm-1
Power Requirements18 volts DC, 3.3 amps, internal battery pack 
Power SupplyUniversal AC/DC provided
Weight5.8 lb. (2.6 kg) with battery -7.0 lbs (3.2 kg)
Dimensions(17 cm) x 7.8" (19.8 cm) x 5.2" (13.2 cm)
Suggested Operating Range5°C - 40°C
Measurement Range0 - 20 & 70 - 98% ethanol in gasoline
Analysis TimeLess than 30 seconds
Instrument Repeatability0 - 20%±0.2%, 20 - 98%±1% of ethanol in petrol concentration
Communication Port USB, RS 232

 

 InfraCal 2 Model ATR-E
Compares to:ASTM D4815
Measurement range:0 - 100% Ethanol in Gasoline
Intrument repeatability:+/- 0.2
  
InfraCal 2 ATR-E, for measuring % Ethanol in Gasoline.
405-2042Model ATR-E Uncalibrated Includes Internal Battery, auto adapter and universal power supply.
405-2042-30Model ATR-E Calibrated: 0-20% & 70-100% Ethanol in Gasoline using P/N's: 403-1026 or 403-1027 Includes Internal Battery, auto adapter and universal power supply.
Accessories 
403-0013Carrying Case for InfraCal Analyzers with pre-diced pluck foam. 18.5" x 14.6" x 8"; 10 lbs.
403-1086Dust Cover
  
Calibration Standard Sets 
403-10265 Point Ethanol Low Concentration Calibration Standard Set Standard concentrations are 0, 5, 10, 15, and 20% ethanol in gasoline. Standards are prepared by a certified laboratory. Each vial contains 20 ml of standard, good for a minimum of 15 tests.
403-10275 Point Ethanol High Concentration Calibration Standard Set Standard concentrations are 70, 80, 90, 95, and 100% ethanol in gasoline. Standards are prepared by a certified laboratory. Each vial contains 20 ml of standard, good for a minimum of 15 tests.