Dari HIOKI PW3360-20 Clamp On Power Logger 0

HIOKI PW3360-20 Clamp On Power Logger

Pembelian Minimum 1
Negara Asal Indonesia
Merek Hioki
Update Terakhir 29 Jan 2016
Harga
Rp 1.234 *harga belum termasuk PPN

Penjual

Toko Indosupply

Verified Supplier
Free Member
Alamat

Jl. Damai Raya, H. Ilyas No.48AD Kec. Pesanggrahan Kel. Petukangan Selatan

No. Telepon

+628XXXXXXXX

No. Whatsapp

Klik Disini

Detil Produk HIOKI PW3360-20 Clamp On Power Logger

HIOKI PW3360-20 Clamp On Power LoggerSupports single to three-phase, 4-wire circuitsMeasure up to 780V with a 1000V display rangeSimultaneously measure up to three single-phase, 2-wire circuits ( in the same power system)Broadly applicable for many jobs, including leakage current measurement ( An op
Dapatkan penawaran terbaik untuk HIOKI PW3360-20 Clamp On Power Logger !
Nama
Jumlah Order
Unit
IndoTrading.com adalah media iklan khusus perusahaan, distributor, Grosir, Agen, Supplier, Trading dan Pabrik. Jika anda tertarik untuk membeli HIOKI PW3360-20 Clamp On Power Logger ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika anda adalah perusahaan yang ingin menjual di IndoTrading.com ,
Detil Produk

HIOKI PW3360-20 Clamp On Power Logger

Supports single to three-phase, 4-wire circuits
Measure up to 780V with a 1000V display range
Simultaneously measure up to three single-phase, 2-wire circuits ( in the same power system)
Broadly applicable for many jobs, including leakage current measurement ( An optional clamp-on leakage sensor supports measurements as low as 50 mA)
Store months of data on SD cards
The QUICK SET function guides you in making the right connections
Choose PW3360-21 for harmonic measurements up to the 40th order
Beli HIOKI PW3360-20 Clamp On Power Logger dengan harga kompetitif dan cari produk dari Test & Measurements, Gratis antar Jakarta dan dapat dikirim keseluruh Indonesia. Dapatkan hanya di toko online kucari, belanja online mudah dan aman.

Spesifikasi - HIOKI PW3360-20 Clamp On Power Logger

Measurement line & number of circuits 50/ 60 Hz, Single phase 2 wires ( 1/ 2/ 3 circuits) , Single phase 3 wires ( 1 circuit) , Three phases 3 wires ( 1 circuit) , Three phases 4 wires ( 1 circuit) , Current only: 1 to 3 channels
Measurement items Voltage/ current RMS, voltage/ current fundamental wave value, voltage / current fundamental wave phase angle, frequency, voltage waveform peak ( absolute value) , current waveform peak ( absolute value) , active/ reactive/ apparent power, power factor ( lag/ lead) or displacement power factor ( lag/ lead) , active energy ( consumption, regeneration) , reactive energy ( consumption, regeneration) , active power demand quantity ( consumption, regeneration) , reactive power demand quantity ( lag/ lead) , active power demand value ( consumption, regeneration) , reactive power demand value ( lag/ lead) , power factor demand, energy cost
Pulse input
[ PW3360-21 only] : Harmonic ( level of voltage/ current/ power, content ratio, phase angle, total value, THD-F, THD-R) , up to 40th order
Voltage ranges 600 V AC
Current ranges 500.00 mA to 5.0000 kA AC ( depends on current sensor in use) ,
50.000 mA to 5.0000 A AC ( Leak clamp on sensor only)
Power ranges 300.00 W to 9.0000 MW ( Depends on voltage/ current combination and measured line type)
Basic accuracy Voltage : ± 0.3% rdg. ± 0.1% f.s
Current : ± 0.3% rdg. ± 0.1% f.s. + clamp sensor accuracy
Active power : ± 0.3% rdg. ± 0.1% f.s. + clamp sensor accuracy ( at power factor = 1)
Display update rate 0.5 sec ( except when accessing SD card or internal memory, or during LAN/ USB communication)
Save destination SD Memory card, or internal memory at real time
Data save interval 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections
Save items Measurement value save: Average only / average, maximum, minimum value
[ PW3360-21 only] : Harmonic data save: Average only / average, maximum, minimum value in binary format
Screen copy: BMP form ( saved every 5 min. at minimum interval time)
Waveform save: Binary waveform data
Interfaces SD memory card
HTTP server function, remote settings via communication program, data download
USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download
Pulse output: proportional to active power consumption when measuring integral power consumption, Isolated open-collector signal
Functions Connection check, Quick Set navigation guide, clock, pulse input
Power supply AC adapter Z1006: ( 100 to 240 V AC, 50/ 60 Hz) , 40 VA ( including AC adapter)
Battery pack 9459: ( DC 7.2 V, 3 VA, charging time 6 hr 10 m) , 8 hours of continuous use ( with back light off)
Dimensions, mass 180 mm ( 7.09 in) W × 100 mm ( 3.94 in) H × 48 mm ( 1.89 in) D, 550 g ( 19.4 oz) without PW9002
180 mm ( 7.09 in) W × 100 mm ( 3.94 in) H × 67.2 mm ( 2.65 in) D, 830 g ( 29.3 oz) with PW9002
Accessories Voltage cord L9438-53 × 1 set, AC adapter Z1006 × 1, USB cable × 1, Instruction manual × 1, Measurement guide × 1, Color spiral tubes × 1 set: red, yellow, blue/ two each, for color-coding clamp sensors, Spiral tubes for grouping clamp sensor cords × 5