Detil Produk Fluke 190-504/AM/S Color ScopeMeter 500 MHz, 4 channels with SCC-290 kit included

Fluke 190-504/AM/S Color ScopeMeter, 500 MHz, 4 channels with SCC-290 kit includedColor ScopeMeter, 500 MHz, 4 channels with SCC-290 kit includedTwo independent floating isolated inputs, up to 1000 VUp to 5 GS/s real time sampling (Depending on model and channels used)Deep memory: 10,000 points per
Dapatkan penawaran terbaik untuk Fluke 190-504/AM/S Color ScopeMeter 500 MHz, 4 channels with SCC-290 kit included !
Nama
Jumlah Order
Unit
IndoTrading.com adalah media iklan khusus perusahaan, distributor, Grosir, Agen, Supplier, Trading dan Pabrik. Jika anda tertarik untuk membeli Fluke 190-504/AM/S Color ScopeMeter 500 MHz, 4 channels with SCC-290 kit included ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika anda adalah perusahaan yang ingin menjual di IndoTrading.com ,
Pencarian Fluke 190-504/AM/S Color ScopeMeter 500 MHz, 4 channels with SCC-290 kit included
Detil Produk

Fluke 190-504/AM/S Color ScopeMeter, 500 MHz, 4 channels with SCC-290 kit included

  • Color ScopeMeter, 500 MHz, 4 channels with SCC-290 kit included
  • Two independent floating isolated inputs, up to 1000 V
  • Up to 5 GS/s real time sampling (Depending on model and channels used)
  • Deep memory: 10,000 points per trace waveform capture (scope mode)
  • CAT III 1000 V/CAT IV 600 V safety rated instrument for industrial environments
  • Up to seven hours of battery operation using BP291
  • Isolated USB host port for direct data storage to a USB memory device; USB device port for easy PC communication
  • Easy access battery door for quick battery swaps in the field
  • Compact and only 2.2 kg (4.8 lb)
  • Security slot: lock down oscilloscope with Kensington® lock while unattended
  • IP 51 rating, dust- and drip-proof
  • Connect-and-View™ triggering for intelligent, automatic triggering on fast, slow and even complex signals
  • Frequency Spectrum using FFT-analysis

 

Manufacturer Specs

Fluke 190 Series190-062190-102190-202190-502190-104190-204190-504
OSCILLOSCOPE MODES
Vertical deflection
Number of channels2222444
Bandwidth60 MHz100 MHz200 MHz500 MHz100 MHz200 MHz500 MHz
Rise time5.8 ns3.5 ns1.7 ns0.7 ns3.5 ns1.7 ns0.7 ns
Number of scope inputs2 input channels plus external trigger4 input channels
Channel architectureAll inputs fully insulated from each other and from ground Inputs may be activated in any combination
Input couplingAC or DC, with ground level indicator
Input sensitivity2 mV/div to 100 V/div, plus variable attenuation
Bandwidth limiterUser selectable: 20 kHz, 20 MHz or full bandwidth
Normal/invert/variableOn each input channel, switched separately
Input voltageCAT III 1000 V/CAT IV 600 V rated, see General Specifications for further details
Vertical resolution8 bit
Accuracy± (2.1 % of reading + 0.04 x range/div) @ 5 mV/div to 100 V/div
Input impedance1 MΩ ± 1 % // 14 pF ± 2 pF
Horizontal
Maximum real-time sample rate (sampled simultaneously)625 MS/s for each channel1.25 GS/s for each channel2.5 GS/s (2ch)5 GS/s (single channel) or 2.5 GS/s (on 2ch)1.25 GS/s for each channel2.5 GS/s (2ch) 1.25 GS/s (4ch)5 GS/s (single channel) or
1.25GS/s per channel
Record lengthUp to 10,000 samples per channel
Time base range
10 ns/div to 4 s/div5 ns/div to 4 s/div2 ns/div to 4 s/div1 ns/div. to 4 s/div.5 ns/div to 4 s/div2 ns/div to 4 s/div1 ns/div to 4 s/div
Time base in a 1-2-4-sequence
Slower time/division settings using ScopeRecord™ Roll mode (see ‘Recorder mode’)
Maximum record length10,000 samples per channel in scope mode;30,000 points per channel in ScopeRecord™ Roll mode (see ‘Recorder mode’)
Timing accuracy± (0.01 % of reading + 1 pixel)
Glitch capture8 ns peak detect on each channel
(using real time sampling and data compression, at any timebase setting)
Display and Acquisition
Display153 mm (6 in) full-color LCD with LED backlight
Display modesAny combination of channels; average on/off; replay
Visible screen width12 divisions horizontally in scope mode
Digital persistence modesoff/short/medium/long/infinite and envelope mode
Waveform mathematicsOne mathematical operation on any 2 input channels: add/subtract/multiply; X-Y-mode Frequency Spectrum using FFT analysis
Acquisition modesNormal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture, waveform compare with automatic “Pass/Fail testing”; Replay
Trigger and Delay
SourceInput A, B or External (via meter input) Input A, B, C or D
ModesAutomatic Connect-and-View™, free run, single shot, edge, delay, dual slope, video, video line, selectable pulsewidth (channel A only), N-cycle
Connect-and-View™Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals. Can be switched off if preferred.
Video triggering (on ch. A)NTSC, PAL, PAL+, SECAM; Includes field 1, field 2 and line select
High-res, non-interlaced videoNon-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz
Pulse width triggering (on channel A)Pulse width qualified by time
Allows for triggering t, =t, ? t, where t is selectable in minimum steps of 0.01 div or 50 ns
Time delay1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay
Dual slope triggeringTriggers on both rising and falling edges alike
N-cycle triggeringTriggers on N-th occurrence of a trigger event; N to be set in the range 2 to 9
Automatic capture of 100 screens
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screens—no specific user setup required. When an anomaly is seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in “baby-sit” mode capturing 100 specified events
ReplayManual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual control. Each screen has date and time-stamp.
Replay storageTwo sets of 100 screens each can be saved internally for later recall and analysis. Direct storage of additional sets on external flash memory drive through USB host port.
FFT—frequency spectrum analysis
Shows frequency content of oscilloscope waveform using Fast Fourier Transform
WindowAutomatic, Hamming, Hanning or None
Automatic windowDigitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant
Vertical scaleLinear/Logarithmic (in volts or amps)
Frequency axisFrequency range automatically set as a function of timebase range of oscilloscope
Waveform compare and pass/fail testing
Waveform CompareProvides storage and display of a reference waveform for visual comparison with newly acquired waveforms. Reference is derived from an acquired waveform and can be modified in the oscilloscope
Pass/FailTesting In waveform compare mode, the oscilloscope can be set up to store only matching (“Pass”) or only non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis
Automatic scope measurements
V dc, V ac rms, V ac+dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac+dc, frequency (in Hz), risetime (using cursors), falltime (using cursors), Power Factor (PF), Watts, VA, VA reactive, phase (between any 2 inputs), pulsewidth (pos./neg.), dutycycle (pos./neg.), temperature °C, temperature °F (not for Japan), dBV, dBm into 50 I and 600 I, VPWM ac and VPWM(ac+dc) for measurement on pulsewidth modulated motordrives and frequency inverters, V/Hz ration (190-xx2 only)
Advanced power and motor drive functionsV/Hz ratio (190-x02 only), Power Factor (PF), Watts, VA, VA reactive, VPWMac and VPWM (ac+dc) for measurement on pulsewidth modulated motordrives and frequency inverters
Advanced functionsmA*s (current-over-time, between cursors);
V*s (voltage over time, between cursors);
W*s (energy, between cursors)
Cursor measurements
SourceOn any input waveform or on mathematical resultant waveform (excl. X-Y-mode)
Dual horizontal linesVoltage at cursor 1 and at cursor 2, voltage between cursors
Dual vertical linesTime between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers, falltime with markers; Vrms between cursors, Watts between cursors
Single vertical lineMin-Max and Average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT Resultant
ZOOMRanges from full record overview to zoom in up to sample level, at any record length
METER MODES
Meter inputsVia 4 mm banana inputs, fully isolated from scope inputs and scope groundVia BNC scope inputs
Number of readingsOne at a timeUp to 4 simultaneously
Maximum resolution5,000 counts999 counts
Input impedance1 MO ± 1 % // 14 pF ± 2 pF
Advanced meter functionsAuto/manual ranging, relative measurements (Zero reference), TrendPlot™ recording
 The specified accuracy is valid over the temperature range 18 °C to 28 °C
Add 10 % of specified accuracy for each degree C below 18 °C or above 28 °C
Voltage
V dc accuracy± (0.5 % + 5 counts)± (1.5 % + 5 counts)
V ac true rms accuracy
15 Hz to 60 Hz:
60 Hz to 1 kHz:
60 Hz to 20 kHz:
± (1 % + 10 counts)
± (2.5 % + 15 counts)
15 Hz to 60 Hz: ± (1.5 % + 10 counts) 60 Hz to 1 kHz:
60 Hz to 20 kHz: ± (2.5 % + 15 counts)
V ac+dc true rms accuracy
15 Hz to 60 Hz:
60 Hz to 1 kHz:
60 Hz to 20 kHz:
± (1 % + 10 counts)
± (2.5 % + 15 counts)
15 Hz to 60 Hz: ± (1.5 % + 10 counts)
Voltmeter ranges500 mV, 5 V, 50 V, 500 V, 1,000 V
Resistance
Ranges500 O, 5 kO, 50 kO, 500 kO, 5 MO, 30 MO
Accuracy± (0.6 % + 5 counts)
Other meter functions
ContinuityBeeper on < 50 O (± 30 O)
Diode testUp to 2.8 V
Current (A)A dc, A ac, A ac+dc using an optional current clamp or shunt
Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A
TemperatureWith optional accessories. Scale factors 1 °C/mV or 1 °F/mV
RECORDER MODES
ScopeRecord™ Roll Mode
Dual or multiple input waveform storage mode, using deep memory
Source and displayInput A, Input B, Dual.
All channels sampled simultaneously.
Any combination of inputs, up to 4 channels. All channels sampled simultaneously.
Bandwidth20 MHz or 20 kHz, user selectable
Memory depth30,000 data points, each holding min/max pair of information
Min/max valuesMin/max values are created at samples that are measured at high sample rate ensuring capture and display of glitches
Recording modesSingle sweep, continuous roll,
Start-on-Trigger (through external),
Stop-on-Trigger (through external)
Single sweep, continuous roll, Start-on-Trigger (through any channel), Stop-on-Trigger (through any channel)
Stop-on-triggerScopeRecord mode can be stopped by an individual trigger event, or by an interruption of a repetitive trigger signal, through any input channel (through External on 190-XX2 Series)
Horizontal scaleTime from start, time of day
ZoomRanges from full record overview to zoom in up to sample level, at any record length
MemoryTwo multiple input ScopeRecord waveforms can be saved internally for later recall and analysis
Direct storage on external flash memory drive through USB host port
ScopeRecord™ Roll mode sample rate and recording timespan
Time base range5 ms/div ~ 2 min/div
Recorded timespan6 sec ~ 48 hr
Time/division in ‘view all’ mode0.5 s/div ~ 4 h/div
Glitch capture8 ns
Sample rate125 MS/s
Resolution200 µsec ~ 4.8 sec
Trendplot™ Recording
Multiple channel electronic paperless recorder. Graphically plots, displays and stores results of up to four automatic scope measurements or a DMM-reading over time.
Source and displayAny combination of scope measurements, made on any of the input channels, or DMM reading (2-channel instruments)
Memory depth18,000 points (sets) per measurement. Each recorded sample point contains a minimum, a maximum and an average value, plus a date- and timestamp.
RangesNormal view: 5 s/div to 30 min/div
In view-all mode: 5 min/div to 48 hr/div (overview of total record)
Recorded time spanUp to 22 days, with a resolution of 102 seconds
Recording modeContinuous recording, starting at 5 s/div with automatic record compression
Measurement speed3 automatic measurements per second or more
Horizontal scaleTime from start, time of day
ZoomUp to 64x zoom-out for full record overview, up to 10x zoom-in for maximum detail
MemoryTwo multiple input TrendPlot records can be saved internally for later recall and analysis Direct storage on external flash memory drive through USB host port
Cursor measurements—all recorder modes
SourceAny waveform trace in any waveform display mode (Scope, ScopeRecord or TrendPlot)
Dual vertical linesCursors may be used to identify Min, Max or Average value of any datapoint in a record, with time between cursors, time from start or absolute time.
GENERAL SPECIFICATIONS
Input voltage range
Rated maximum floating voltageCAT III 1000 V/CAT IV 600 V (maximum voltage between any contact and earth-ground voltage level)
Probe input voltage VPS410CAT III 1000 V/CAT IV 600 V (Maximum voltage between 10:1 probe tip and reference lead)
Probe input voltage VPS510CAT III 300 V (Maximum voltage between 10:1 probe tip and reference lead)
Maximum BNC input voltageCAT IV 300 V (maximum voltage on BNC input directly)
Maximum voltage on meter inputCAT III 1000 V/CAT IV 600 V
(safety designed banana input connectors) —
Memory save and recall
Memory locations (internal)30 waveform memories plus 10 recording memories plus 9 screen copy memories (190-XX, 2 channel models); 15 waveforms memories plus 2 recording memories plus 1 screen copy memory (190-XX, 4 channel models)
15 waveform memory locationsStores Scope-trace waveform data (2 or 4 traces each) plus screen-copy plus corresponding setup
Two recording memoriesEach may contain:
• a 100 Screen Replay sequence, or
• a ScopeRecord Roll-mode recording (2 or 4 traces), or
• a TrendPlot recording of up to 4 measurements
External data storage• On PC, using FlukeView™ Software, or
• Direct storage on external flash memory drive (maximum 2 GB) through USB host port
Screencopies• On PC, using FlukeView™ Software, or
• Internally (in instrument) which can be copied on to external flash memory drive as .BMP-file, through USB host port
VolatilityMeasurement data is initially stored in RAM, which is maintained by the main battery with a 30 seconds back-up when battery is exchanged When storing data, this is written in non-volatile flash-ROM
Real-time clockProvides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences and for TrendPlot recordings
Case
DesignRugged, shock-proof with integrated protective holster. Handstrap and hangstrap included as standard Kensington lock supported to lock down instrument when left unattended
Drip and dust proofIP 51 according to IEC529
Shock and vibrationShock 30 g, vibration (sinusoidal) 3 g according to MIL-PRF-28800F Class 2
Display size127 mm x 88 mm (153 mm/6.0 in diagonal) LCD
Resolution320 x 240 pixels
Contrast and brightnessUser adjustable, temperature compensated
Brightness200 cd/m2 typ. using power adapter, 90 cd/m2 typical using battery power
Mechanical data
Size265 mm x 190 mm x 70 mm (10.4 in x 7.5 in x 2.8 in)
Weight (including battery)2.1 kg (4.6 lb) 2.2 kg (4.8 lb)
Power
Line powerMains adapter/battery charger BC190 included, version depending of country
Battery powerRe-chargeable double capacity Li-Ion battery (included). Battery swappable through easily accessible battery door at the rear of the instrument
Battery type (incl.) and capacity [+opt. battery]BP290; 2400 mAh
[BP291 (4800 mAh) optional]
BP291; 4800 mAh
Battery charge indicatorBattery has built-in status indicator for use with external charger, next to battery status indicator on instrument screen
Battery operating time (with backlight low)Up to four hours using BP290 (included), Up to eight hours using BP291 (optional)Up to seven hours using BP291 (included)
Battery charging time2½ hours using BP290; 5 hours using BP291 Five hours BP291
Battery power saving functionsAuto ‘power down’ with adjustable power down time; Auto ‘Display off’ with adjustable power down time; On-screen battery power indicator
Safety
ComplianceEN61010-1-2001, Pollution Degree 2; CAN/CSA C22.2, No. 61010-1-04, with approval; UL61010B; ANSI/ISA-82.02.01
Environmental
Operating temperature0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery
Storage temperature-20 °C ~ +60 °C
Humidity+10 °C ~ +30 °C: 95 % RH non-condensing;
+30 °C ~ +40 °C: 75 % RH non-condensing;
+40 °C ~ +50 °C: 45 % RH non-condensing
Maximum operating altitudeUp to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V;
up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Maximum storage altitude12 km (40,000 ft)
Electro-Magnetic- Compatibility (EMC)EN 61326 (2005-12) for emission and immunity
InterfacesTwo USB-ports provided. Ports are fully insulated from instrument’s floating measurement circuitry USB-host port directly connects to external flash memory drive (up to 2 GB) for storage of waveform data, complete datasets in which data and setup information is included, instrument settings and screen copies A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer under PC-control
Probe calibration outputDedicated probe-cal output with reference contact provided, fully insulated from any measurement input channel
WarrantyThree years (parts and labor) on main instrument, one year on accessories
Included accessories
Battery charger/mains adapterBC190
Li-Ion battery packBP290 (2400 mAh)BP291 (4800 mAh)
Voltage probe sets. Each set includes ground lead, hook clip, ground spring and probe tip insulation sleeve.VPS410 (one red, one blue)VPS410 (one red, one grey, one blue, one green)
Test leadsTL175 (one red, one black) with test pins(N/A)
Voltage ProbesVPS410-x: each set includes: Ground lead, hook clip, ground spring and probe tip insulation sleeve. VPS510-x: each set includes: Ground lead, hook clip, ground spring, probe tip insulation sleeve and BNC-to probe tip adapter.
OtherLi-Ion battery (BP290 or BP291, see above); Battery charger (BC190); Hangstrap; Handstrip (user selectable for left- or right hand use); Multi language users manuals on CD-ROM; FlukeView® demo package (with restricted functionality); USB interface cable for PC connectivity.

 