Controller ICJual  Controller LK G5001 ModelLK-G5001TypeSeparate type Main controllerSensor head compatibilityCompatibleNo. of connectable sensor heads2DisplayMinimum display unit0.001 µmDisplay range±999.999 µm to ±9999.99 mm (7 settings selectable)Display c
Dapatkan penawaran terbaik untuk Controller LK G5001 !
Nama
Jumlah Order
Unit
IndoTrading.com adalah media iklan khusus perusahaan, distributor, Grosir, Agen, Supplier, Trading dan Pabrik. Jika anda tertarik untuk membeli Controller LK G5001 ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika anda adalah perusahaan yang ingin menjual di IndoTrading.com ,
Detil Produk

Controller IC

Jual  Controller LK G5001 

Model

LK-G5001

Type

Separate type Main controller

Sensor head compatibility

Compatible

No. of connectable sensor heads

2

Display

Minimum display unit

0.001 µm

Display range

±999.999 µm to ±9999.99 mm (7 settings selectable)

Display cycle

Approx 10 times/sec.

Display interface

Display port

Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected

LED indicator

LASER ON

Terminal block

Analog output voltage

±10 V output, Output impedance: 100 Ω*1

Analog current output

4 to 20 mA, Maximum load resistance: 350 Ω*1

No. of analog outputs

2*1

TIMING 1 input

Non-voltage input*2

RESET 1 input

Auto-zero 1 input

Laser remote input

Non-voltage input*1

Alarm output

NPN open-collector output*1

General comparator output

Expansion connector

TIMING input

Non-voltage input*1

RESET input

Auto-zero input

Program switching input

Binary selection input

Alarm output

NPN open-collector output*1

Comparator output

Binary output

RS-232C interface

Baud rate: 9600 to 115200 bps
Data length: 8 bits Stop bit length: 1 bit Parity: None/even/odd

USB interface

USB 2.0 Hi-Speed compliant*3

Ethernet interface

100Base-TX/10Base-T*4

EtherNet/IPTMinterface

Cyclic communication (implicit messaging)
Message communication (explicit messaging) : UCMM and Class3 Number of connections: 32 Complies with conformance test version CT14*5

Head expansion unit connector

Up to 10 head expansion units can be connected to one main controller

Expansion unit connector

Either of the CC-Link unit (LK-CC100) or DeviceNetTM unit (LK-DN100) can be connected

Power supply

Power supply voltage

24 VDC ±10%

Maximum current consumption

0.6 A or less with 1 head/3.5 A or less with 12 heads

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C 32 to 122 °F.
When two or more head expansion units are connected: 0 to +40 °C 32 to 104 °F.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 600 g

*1 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max.
Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA
Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual.
*2 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.
PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max.
Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max.
Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA
Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual. This input is applied to all of the synchronized OUT.
*3 When a PC supporting USB 1.1 or USB 2.0 full speed is connected, the data refresh cycle and other operations may slow down.
*4 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units.
*5 The EtherNet/IPTM interface cannot be used when a CC-Link unit or a DeviceNetTM unit is installed.
EtherNet/IPTM is supported by the latest controllers. For details on which controllers support EtherNet/IPTM , contact your nearest KEYENCE office.