Dari 4700100 HACH 2100AN Laboratory Turbidimeter EPA 115 Vac  0

4700100 HACH 2100AN Laboratory Turbidimeter EPA 115 Vac

Pembelian Minimum 1
Negara Asal United States
Merek Hach
Update Terakhir 07 Jun 2016
Harga
CALL

Penjual

CV. Andalan Prima Sejahtera Medan

Verified Supplier
Alamat

Jl. Jamin Ginting Km. 9,5 Gg. Budi Bukit No. 6

No. Telepon

+628XXXXXXXX

No. Whatsapp

Klik Disini

Detil Produk 4700100 HACH 2100AN Laboratory Turbidimeter EPA 115 Vac

Alat LaboratoriumEnhanced performance for the demanding user.Hach 2100 Series Laboratory Turbidimeters are engineered to provide superior accuracy and sensitivity in any application. The 2100AN is equipped with a stable halogen-filled tungsten filament lamp to meet the reporting requirements of EPA
Dapatkan penawaran terbaik untuk 4700100 HACH 2100AN Laboratory Turbidimeter EPA 115 Vac !
Nama
Jumlah Order
Unit
IndoTrading.com adalah media iklan khusus perusahaan, distributor, Grosir, Agen, Supplier, Trading dan Pabrik. Jika anda tertarik untuk membeli 4700100 HACH 2100AN Laboratory Turbidimeter EPA 115 Vac ini dengan harga murah, Mohon hubungi Kontak Perusahaan ini diatas.

Jika anda adalah perusahaan yang ingin menjual di IndoTrading.com ,
Pencarian 4700100 HACH 2100AN Laboratory Turbidimeter EPA 115 Vac
Detil Produk

Alat Laboratorium

Enhanced performance for the demanding user.

Hach 2100 Series Laboratory Turbidimeters are engineered to provide superior accuracy and sensitivity in any application. The 2100AN is equipped with a stable halogen-filled tungsten filament lamp to meet the reporting requirements of EPA Method 180.1. This model is ideal for testing higher ranges of turbidity up to 10,000 NTU. Additional absorbance, transmittance, and color measurement modes make the 2100AN the most flexible of any Hach benchtop turbidimeter.

  • Ratio technology provides highly accurate results
  • Interchangeable color filters provide ultimate flexibility
  • Optional cell adapters for the 2100AN Turbidimeter allow measurement of smaller sample volumes
  • Built-in printer provides a record of calibration and measurement data
  • Air purge prevents condensation in the sample chamber of the 2100AN

Ratio technology provides highly accurate results

One keystroke initiates ratio measurement and activates an array of detectors in addition to the 90-degree nephelometric detector. Ratio measurement corrects for color interference, enhances calibration stability, and allows the measurement of turbidity at levels greater than 1000 NTU.


Interchangeable color filters provide ultimate flexibility

A variety of filter module assemblies are available to select the wavelength of light used for measuring samples. The instrument is supplied with an EPA filter assembly for turbidity measurement and a 455 nm filter assembly for use in APHA Pt-Co color measurement. Additional filter assemblies, including an 860 nm option for ISO 7027 compliance, are available as optional accessories for custom applications.


Optional cell adapters for the 2100AN Turbidimeter allow measurement of smaller sample volumes

Measure samples as small as 2.5 mL with Hach bencthop turbidimeters. Use the Application Specific Calibration ability of the instrument to provide direct reading of results with 12, 13, 16, or 19 mm sample vials. Small diameter sample cells are useful when only a small quantity of sample is available, the sample to be measured is ampuled and cannot be opened, or the sample is too turbid to be measured with the standard sample cell without dilution.

Built-in printer provides a record of calibration and measurement data

On-board printer saves bench space. Print interval feature automatically prints a displayed reading at selected print intervals.

Air purge prevents condensation in the sample chamber of the 2100AN

Measure cold and hot samples. A built-in connection is provided to purge the sample compartment with dry air to prevent light scattering caused by condensation.